The following Verilog code is intended to implement a 3-bit up-counter. H…
The following Verilog code is intended to implement a 3-bit up-counter. However, it contains a logical error and doesn’t produce the correct count sequence. Identify the error and fix the code.
Model answer
The logical error in the code is the incorrect sensitivity list in the always block. The reset condition should be checked separately from the clock edge. The correct code is as follows: In this corrected code, the reset condition is checked only on the positive edge of the clock, and the 3-bit up-counter works as expected.